Debug Views

Look Inside your Jumperless

You type all of these at the terminal prompt. n is on the menu you always see, b and c show up once you press e, and C isn't listed anywhere but it still works.

Crossbar Array

To see what the 12 analog crossbar switches are up to, just enter C

Crossbar View

Lowercase c will show a compact version

Crossbar Compact

You can also set it to live updating mode with c!. A second c! turns it back off, or use c0 and c1 to force it off and on. Turning it on clears the screen and pins the crossbar to the top of the terminal, and everything else scrolls underneath it. The live view only draws on the main serial port.


Bridge Array

Enter b. This is generally the most helpful one for me to troubleshoot what's going on if your issue has anything to do with routing or connections. It probably looks like nonsense to you but I've been in it so long it makes perfect sense to me. (there's an older version of this output in this Crowd Supply update)

It prints your duplicate stacking settings first, then the bridge array, then the paths, then the chip status. b0 shows every path instead of just the routed duplicates, and b2 shows every duplicate.

Screenshot 2025-05-30 at 7 04 54 AM


Net List

Enter n to show this one. If you have an ADC, a gpio input, or a gpio output routed to a net, it'll stay up and live update when those readings change, or when you move the clickwheel highlight. Any key ends it, and so does a probe button press or a click of the clickwheel. That key doesn't get eaten though, it runs as your next command, so press Enter or space to get out quietly rather than a letter that does something (x would clear all your connections).

Screenshot 2025-05-30 at 7 10 04 AM


Scan

Apps > Scan on the click wheel goes through every row and prints the voltage on it, rows with nothing on them come out as floating (that's how you tell a floating row from one that's tied to GND, which reads 0V). It keeps looping until you type something or click the wheel.